Auxiliary Contact
Auxiliary Contact
Auxiliary Contact
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13
AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC
DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz
DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13
AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D
Acti 9
C6-
Tesys
TeSys D
Acti 9
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
IEC 60947-3
IEC 60947-5
EN/IEC 60947-5-1
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
IEC 60947-3
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14
690 V conforming to IEC 60947-1
300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1
500 V
690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14
690 V conforming to IEC 60947-1
IP Degree of Protection
IP2X conforming to IEC 60529
IP2X
IP20 conforming to IEC 60529
IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
IP2X conforming to IEC 60529
IP2X
Programmable Logic Controllers
Programmable Logic Controllers
Programmable Logic Controllers
Product Or Component Type
Discrete I/O extension module
Modular smart relay
Compact smart relay
Compact discovery packs
Discrete I/O extension module
Modular smart relay
Range Of Product
Modicon M251
Easy Modicon M200
Modicon M221
Modicon M171/M172
Modicon M251
Easy Modicon M200
Standards
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01
CAN/CSA-E60730-1<br />CSA E60730-2-9<br />EN 60068-2-27<br />EN 60068-2-6 Fc<br />EN 60730-1<br />EN 60730-2-9<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-2<br />IEC 61000-4-3<br />IEC 61000-4-4<br />IEC 61000-4-5<br />IEC 61000-4-6<br />IEC 61000-4-11<br />UL94 (material V0)
IEC 61000-4-5<br />IEC 61000-4-3<br />IEC 61000-4-2<br />EN 60068-2-27<br />EN 60730-1<br />EN 60068-2-6 Fc<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-4<br />CAN/CSA-E60730-1<br />IEC 61000-4-11<br />IEC 61000-4-6<br />CSA E60730-2-9<br />EN 60730-2-9<br />UL94 (material V0)
CSA, UL
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01
CAN/CSA-E60730-1<br />CSA E60730-2-9<br />EN 60068-2-27<br />EN 60068-2-6 Fc<br />EN 60730-1<br />EN 60730-2-9<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-2<br />IEC 61000-4-3<br />IEC 61000-4-4<br />IEC 61000-4-5<br />IEC 61000-4-6<br />IEC 61000-4-11<br />UL94 (material V0)
Ambient Air Temperature For Operation
-10…35 °C (vertical installation) -10…55 °C (horizontal installation)
-10…50 °C (vertical installation) -10…55 °C (horizontal installation)
-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…65 °C conforming to UL 60730-1<br />-20…60 °C horizontal conforming to UL 60730-1
-10…35 °C (vertical installation) -10…55 °C (horizontal installation)
-10…50 °C (vertical installation) -10…55 °C (horizontal installation)
Product Certifications
GL C-Tick CSA UL GOST
GOST CSA UL C-Tick GL
DNV-GL EAC ABS cULus LR RCM CE UKCA cULus HazLoc
EAC<br />CE<br />cURus<br />CSA<br />RCM