Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric METSEPM5341 Power Meter Powerlogic PM5341, Ethernet, up to 31st Harmonic, 256KB 2DI/2DO 35 Alarms, Mid
Schneider Electric METSEPM5341 Power Meter Powerlogic PM5341, Ethernet, up to 31st Harmonic, 256KB 2DI/2DO 35 Alarms, Mid
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
PowerLogic
[In] Rated Current
5 A 1 A
Type of Measurement
Current Voltage Frequency Power factor Energy Active and reactive power
Display Type
Monochrome graphic LCD
Standards
IEC 60529 UL 61010-1 IEC 61557-12:2015 IEC 62053-24 IEC 62053-22:2020 EN 50470-3 EN 50470-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display
Width
96 mm
This spec is not available in the specification table.
Device Short Name
PM5341
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM5000
This spec is not available in the specification table.
Depth
72 mm
This spec is not available in the specification table.
Device Application
Power monitoring Multi-tariff
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Flush-mounted
This spec is not available in the specification table.
Accuracy class
Class 0.5S active energy conforming to IEC 62053-22
This spec is not available in the specification table.
Network Frequency
50 Hz 60 Hz
This spec is not available in the specification table.
Sampling rate
64 samples/cycle
This spec is not available in the specification table.
Measurement current
5…8500 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V BACnet IP
This spec is not available in the specification table.
Communication port support
ETHERNET
This spec is not available in the specification table.
Number of inputs
2 digital
This spec is not available in the specification table.
Number of outputs
2 relay 2 digital
This spec is not available in the specification table.
Connections - Terminals
Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 MID conforming to EN 50470-1 MID conforming to EN 50470-3
This spec is not available in the specification table.
IP Degree of Protection
IP54 display: conforming to IEC 60529 IP30 rear: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C non-condensing
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
2000 m CAT III 3000 m CAT II
This spec is not available in the specification table.
Power quality analysis
up to the 31st harmonic
This spec is not available in the specification table.
supply voltage
90...450 V AC 45...65 Hz 100...300 V DC
This spec is not available in the specification table.
type of network
1P + N 3P + N 3P
This spec is not available in the specification table.
Maximum power consumption in VA
11 VA at 415 V
This spec is not available in the specification table.
Ride-through time
80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical 50 ms 125 V DC typical
This spec is not available in the specification table.
Display resolution
128 x 128 pixels
This spec is not available in the specification table.
Analogue input type
Voltage (impedance 10 MOhm) Current (impedance <= 0.3 mOhm)
This spec is not available in the specification table.
Measurement voltage
35…760 V AC 45...65 Hz between phases 20…400 V AC 45...65 Hz between phase and neutral
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 %
This spec is not available in the specification table.
data recording
Alarm logs Time stamping Min/max of instantaneous values Event logs Maintenance logs Data logs
This spec is not available in the specification table.
Electromagnetic Compatibility
Limits for harmonic current emissions class A conforming to IEC 61000-3-2 Electrostatic discharge level 4 conforming to IEC 61000-4-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022
This spec is not available in the specification table.
Information displayed
Tariff (4)
This spec is not available in the specification table.
memory capacity
256 kB
This spec is not available in the specification table.
Product Description
S$ 1,452.60
(exc. GST)
S$ 1,583.33
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
38 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 3P 1P + N, 3P + N 1P + N 3P, 3P 3P + N 1P + N, 1P + N
[In] Rated Current
5 A 1 A, 1 A 5 A 10 A, 1 A 5 A, 125 A, 63 A
Type of Measurement
Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average, Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Active and reactive energy Active and reactive power Current Voltage, Active energy Current Voltage Active power
Display Type
Backlit LCD, Remote LCD, TFT LCD, Without display, No Display
Standards
BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.16, IEC 62053-22:2020 EN 50470-1 IEC 60529 IEC 61557-12:2015 UL 61010-1 EN 50470-3 IEC 62053-24 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22:2020 IEC 62053-22:2020 EN 62052-22 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20, IEC 62052-31 IEC 62053-21 IEC 62053-23 IEC 62052-11, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…55 °C -20…55 °C, -25…55 °C - MID -25…70 °C - IEC, -25…70 °C - IEC
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top