Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric GV2ME14 Motor Circuit Breaker, Tesys Deca, 3P, 6 to 10A, Thermal Magnetic, Screw Clamp Terminals, Button Control
Schneider Electric GV2ME14 Motor Circuit Breaker, Tesys Deca, 3P, 6 to 10A, Thermal Magnetic, Screw Clamp Terminals, Button Control
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Motor Protection Circuit Breakers dimensions or variations
Please select at least one specification below.
Poles
3P
Rated Current
10 A
Colour
Dark grey
Trip Unit Technology
Thermal-magnetic
Control Type
Push-button
Range
TeSys Deca
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-2
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-20…60 °C
Ambient Air Temperature for Storage
-40…80 °C
Operating Altitude
2000 m
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Width
45 mm
This spec is not available in the specification table.
Device Short Name
GV2ME
This spec is not available in the specification table.
Product Name
TeSys GV2 TeSys Deca
This spec is not available in the specification table.
Depth
78.5 mm
This spec is not available in the specification table.
Device Application
Motor protection
This spec is not available in the specification table.
Network Type
AC
This spec is not available in the specification table.
Network Frequency
50/60 Hz conforming to IEC 60947-4-1
This spec is not available in the specification table.
Utilisation Category
Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-1 § 7-1-6
This spec is not available in the specification table.
Standards
EN/IEC 60947-2 EN/IEC 60947-4-1
This spec is not available in the specification table.
Height
89 mm
This spec is not available in the specification table.
Mechanical Durability
100000 cycles
This spec is not available in the specification table.
Electrical Durability
100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
This spec is not available in the specification table.
Tightening Torque
1.7 N.m - on screw clamp terminal
This spec is not available in the specification table.
Fixing Mode
35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
This spec is not available in the specification table.
Motor Power kW
3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 5.5 kW at 690 V AC 50/60 Hz 7.5 kW at 690 V AC 50/60 Hz
This spec is not available in the specification table.
[Ith] conventional free air thermal current
10 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
2.5 W
This spec is not available in the specification table.
Product certifications
CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV RINA DNV-GL UKCA
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz
This spec is not available in the specification table.
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Thermal protection adjustment range
6…10 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Magnetic tripping current
138 A
This spec is not available in the specification table.
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
This spec is not available in the specification table.
Rated duty
Continuous conforming to IEC 60947-4-1
This spec is not available in the specification table.
IK Degree of Protection
IK04
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Protection Circuit Breakers from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Protection Circuit Breakers
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top