Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric GS1LLD3 Switch Disconnector Fuse, Tesys Gs, 3P, 3NO, 160A, 12W, Fuse Type Din, Size 00
Schneider Electric GS1LLD3 Switch Disconnector Fuse, Tesys Gs, 3P, 3NO, 160A, 12W, Fuse Type Din, Size 00
Image
Image
Product Description

Schneider Electric GS1LLD3 Switch Disconnector Fuse, Tesys Gs, 3P, 3NO, 160A, 12W, Fuse Type Din, Size 00

TeSys GS fuse switch-disconnector, 3 poles (3P), 160A/750V, to be used with DIN blade fuse links size 00 up to 160A, for motor applications up to 80kW@400V AC-23. To be equipped with a direct operating handle GS1AH02 (to be ordered separately), for using an external operating handle select a fuse switch-disconnector type GS2LL. Screw terminals to be equipped with upstream and downstream 3P terminal shrouds GS1AP33 (to be ordered separately), it provides high short circuit current rating 100kA@400V. Add-on auxiliary contact modules, front mounting GS1AM (early-break and position signaling), side mounting GS1AN (position signaling) can complete the assembly (to be ordered separately). Type aM and gG size 00 blade fuse links without strickers DF2GA, DF2GN are available (to be ordered separately). Multi standards certified (IEC, Marine), Green Premium compliant (RoHS/REACh).

Main

  • Range: TeSys
  • Product name: TeSys GS
  • Device short name: GS1 L
  • Product or component type: Switch-disconnector-fuse
  • Device application: Protection
  • Poles description: 3P
  • Protected poles description: 3t
  • Contacts type and composition: 3 NO
  • [Ith] conventional free air thermal current: 160 A (at 40 °C)
  • [Ie] rated operational current:
    • 125 A at 440 V 2 poles in series per phase DC-23A
    • 125 A at 440 V 2 poles in series per phase DC-23B
    • 125 A at 690 V with terminal cover AC-23A
    • 125 A at 690 V with terminal cover AC-23B
    • 160 A at 400 V AC-23A
    • 160 A at 400 V AC-23B
    • 160 A at 500 V AC-23A
    • 160 A at 500 V AC-23B
  • Fuse type: DIN
  • Fuse size: 00
  • Network type: AC, DC
  • Network frequency: 50/60 Hz
  • Type of operating handle: Direct right side
  • Mounting support: Plate
  • [Ui] rated insulation voltage: 750 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage: 8 kV
  • Rated operational power in W:
    • 90 kW at 400 V
    • 110 kW at 500 V
    • 110 kW at 690 V
  • Breaking capacity: 12 W
  • Making capacity:
    • 1600 A at 400 V AC-23B
  • Breaking capacity:
    • 1280 A at 400 V (AC-23B)
  • Short-circuit withstand: 22.7 kA
  • Mechanical durability: 10000 cycles
  • Electrical durability:
    • 1000 cycles AC-23A
    • 1000 cycles AC-23B
    • 200 cycles DC-23A
    • 200 cycles DC-23B
  • Connections - terminals:
    • Power circuit: bars
    • Power circuit: lugs-ring terminals 50…95 mm² flexible
  • [Icm] rated short-circuit making capacity: 100 kA at 400 V with protection by gG fuses
  • Tightening torque:
    • Power circuit: 12 N.m - on bars
    • Power circuit: 12 N.m - on lugs-ring terminals

Complementary

  • Type of operating handle: Direct right side
  • Mounting support: Plate
  • [Ui] rated insulation voltage: 750 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage: 8 kV
  • Rated operational power in W:
    • 90 kW at 400 V
    • 110 kW at 500 V
    • 110 kW at 690 V
  • Breaking capacity: 12 W
  • Making capacity:
    • 1600 A at 400 V AC-23B
  • Breaking capacity:
    • 1280 A at 400 V (AC-23B)
  • Short-circuit withstand: 22.7 kA
  • Mechanical durability: 10000 cycles
  • Electrical durability:
    • 1000 cycles AC-23A
    • 1000 cycles AC-23B
    • 200 cycles DC-23A
    • 200 cycles DC-23B
  • Connections - terminals:
    • Power circuit: bars
    • Power circuit: lugs-ring terminals 50…95 mm² flexible
  • [Icm] rated short-circuit making capacity: 100 kA at 400 V with protection by gG fuses
  • Tightening torque:
    • Power circuit: 12 N.m - on bars
    • Power circuit: 12 N.m - on lugs-ring terminals

Environment

  • Standards: IEC 60947-3
  • Product certifications: CE
  • Protective treatment: TH
  • IP degree of protection: IP20 conforming to IEC 60529 (with terminal cover)
  • Ambient air temperature for operation: -20…70 °C
  • Ambient air temperature for storage: -40…80 °C
  • Fire resistance:
    • 850 °C fuse cover conforming to IEC 60695-2-1
    • 960 °C body conforming to IEC 60695-2-1
  • Height: 162 mm
  • Width: 150 mm
  • Depth: 126.5 mm
  • Net weight: 1.8 kg
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Fuse Switch Disconnectors from SCHNEIDER ELECTRIC
Source & compare similar products
More from Fuse Switch Disconnectors
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top