Specifications
infotip-icon
View other Power Supply dimensions or variations
Please select at least one specification below.
Standards
CSA C22.2 No 60950-1 UL 508 EN/IEC 62368-1
Connections - Terminals
Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection
Product Certifications
CCSAus EAC KC RCM UL
Inrush Current
30 A
Status Led
1 LED (green and red) output voltage 1 LED (green, red and orange) output current
Power Supply Output Current
20 A
Product Or Component Type
Power supply
This spec is not available in the specification table.
Range Of Product
Modicon Power Supply
This spec is not available in the specification table.
Mounting Support
35 x 7.5 mm symmetrical DIN rail 35 x 15 mm symmetrical DIN rail
This spec is not available in the specification table.
Efficiency
88 %
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 conforming to IEC 60529 IP10
This spec is not available in the specification table.
Ambient Air Temperature For Operation
50…60 °C with derating factor mounting position A < 2000 m -25…50 °C without derating mounting position A < 2000 m
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Environmental Characteristic
EMC conforming to IEC 61000-6-1 EMC conforming to IEC 61000-6-3 EMC conforming to EN 55024 EMC conforming to IEC 61000-6-4 EMC conforming to EN/IEC 61204-3 Safety conforming to IEC 60950-1 Safety conforming to EN/IEC 61204-3
This spec is not available in the specification table.
Operating Position
Vertical
This spec is not available in the specification table.
Dielectric Strength
2500 V with between input and ground 3000 V with between input and output 500 V with between output and ground
This spec is not available in the specification table.
Output Voltage
24 V DC
This spec is not available in the specification table.
Provided Equipment
Power factor correction filter conforming to IEC 61000-3-2
This spec is not available in the specification table.
Supply
SELV conforming to IEC 60950-1 SELV conforming to IEC 60204-1 SELV conforming to IEC 60364-4-41
This spec is not available in the specification table.
Power Supply Type
Regulated switch mode
This spec is not available in the specification table.
Nominal Input Voltage
100...120 V AC single phase, terminal(s): N-L1 200...240 V AC phase to phase, terminal(s): L1-L2
This spec is not available in the specification table.
Rated Power In W
480 W
This spec is not available in the specification table.
Input Voltage Limits
85...132 V AC 170...264 V AC
This spec is not available in the specification table.
Power Factor
0.68 at 240 V AC 0.69 at 120 V AC
This spec is not available in the specification table.
Output Voltage Adjustment
24...28.8 V adjustable
This spec is not available in the specification table.
Power Dissipation In W
57.6 W
This spec is not available in the specification table.
Output Protection Type
Against overload, protection technology: manual or automatic reset Against overvoltage, protection technology: 30...32 V, manual reset Against short-circuits, protection technology: manual or automatic reset Against undervoltage, protection technology: tripping if U < 21.6 V Thermal, protection technology: automatic reset
This spec is not available in the specification table.
Output Coupling
Series Parallel
This spec is not available in the specification table.
Permissible Temporary Current Boost
1.5 x In (for 4 s)
This spec is not available in the specification table.
Anti-Harmonic Filter
Low frequency harmonic currents
This spec is not available in the specification table.
Product Description
S$ 681.50
(exc. GST)
S$ 742.84
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Power Supply
23 Items
power-supply-img
Standards
CSA C22.2 No 60950-1 UL 508 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 UL 508 CSA C22.2 No 107.1 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 IEC 60335-1 EN/IEC 62368-1, UL 508 CSA C22.2 No 60950-1 EN/IEC 62368-1, CSA C22.2 No 60950-1 UL 508
Connections - Terminals
Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection, Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) for output Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) for input, For ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 12, Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output ground connection, For output connection: screw type terminals, connection capacity: 2 x 0.5...2 x 10 mm² AWG 20...AWG 8 For input connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 20...AWG 8 For diagnostic relay: removable screw terminal block, connection capacity: 1 x 2.5 mm² AWG 14
Product Certifications
CCSAus EAC UL RCM KC, CE CUL listed CUL recognized RCM CB Scheme EAC KC, CE CULus EAC RCM CB Scheme KC, CCSAus EAC KC RCM UL, EAC RCM
Inrush Current
45 A at 100...240 V AC, 35 A at 115 V 70 A at 230 V, 40.0 A at 115 V 80.0 A at 230 V, 50 A at 100...240 V AC, 30 A
Power Supply Output Current
2.2 A, 2.5 A, 6.25 A, 3.13 A, 5 A
-
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power Supply from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power Supply
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top