Range
Acti9
Poles Description
1P + N
[In] Rated Current
63 A
Type of Measurement
Active and reactive energy Active and reactive power Current Voltage
Rated Voltage
230 V +/- 20 %
Display Type
LCD display
Standards
IEC 62052-31 IEC 62053-21 IEC 62053-23 IEC 62052-11
Ambient Air Temperature for Operation
-25…55 °C
Colour
White
This spec is not available in the specification table.
Width
36 mm
This spec is not available in the specification table.
Local Signalling
Red LED: accuracy checking 1...1000 p/kWh
This spec is not available in the specification table.
Device Short Name
iEM2110
This spec is not available in the specification table.
Product or Component Type
Energy meter
This spec is not available in the specification table.
Depth
70 mm
This spec is not available in the specification table.
Device Application
Sub billing Partial meter Multi-tariff
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Height
90 mm
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Accuracy class
Class 1 active energy conforming to IEC 62053-21 Class B active energy conforming to EN 50470-3 Class 2 reactive energy conforming to IEC 62053-23
This spec is not available in the specification table.
input type
Direct input
This spec is not available in the specification table.
Network Frequency
60 Hz 50 Hz
This spec is not available in the specification table.
Technology Type
Electronic
This spec is not available in the specification table.
Sampling rate
32 samples/cycle
This spec is not available in the specification table.
Measurement current
0.25…63 A
This spec is not available in the specification table.
Maximum value measured
999999.99 kWh
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV 1.2/50 µs
This spec is not available in the specification table.
Connections - Terminals
Power circuit: tunnel type terminals (bottom) 1 1.65…33 mm² cable(s) solid Power circuit: tunnel type terminals (bottom) 1 1.65…33 mm² cable(s) stranded with cable end Pulse output: screw clamp terminals (top) 1 1…4 mm² cable(s) solid Pulse output: screw clamp terminals (top) 1 1…2.5 mm² cable(s) stranded with cable end
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
9 mm Pitches
4
This spec is not available in the specification table.
Product certifications
MID conforming to EN 50470-1 MID conforming to EN 50470-3 CE
This spec is not available in the specification table.
IP Degree of Protection
IP40 front panel: conforming to IEC 60529 IP20 casing:
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
0…95 % at 55 °C
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-25…70 °C
This spec is not available in the specification table.
Wire Stripping Length
Power circuit: 17 mm Pulse output: 6 mm
This spec is not available in the specification table.
Operating Altitude
< 2000 m
This spec is not available in the specification table.
Tightening Torque
Power circuit: 2 N.m PZ2 screwdriver Pulse output: 0.5 N.m3.5 mm
This spec is not available in the specification table.
supply voltage
96...276 V AC 50 Hz
This spec is not available in the specification table.
Maximum power consumption in VA
3 VA at 240 V AC
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Flame retardance
V0 conforming to UL 94
This spec is not available in the specification table.
Metering type
Active, reactive, apparent energy (signed, four quadrant)
This spec is not available in the specification table.
impulse duration
30...100 ms
This spec is not available in the specification table.
Maximum current [Imax]
63 A
This spec is not available in the specification table.
[Ib] basic current
5 A
This spec is not available in the specification table.
Output voltage
3...33 V AC@90 mA 5...70 V DC@90 mA
This spec is not available in the specification table.
Maximum power consumption in W
1 W
This spec is not available in the specification table.
Display digits
8
This spec is not available in the specification table.
family
Acti9 iEM2100
This spec is not available in the specification table.
Tariff counter
Tariff (2)
This spec is not available in the specification table.
Digital inputs
1 digital
This spec is not available in the specification table.
Digital outputs
2 pulse energy monitoring:
This spec is not available in the specification table.
Product Description
S$ 538.00
(exc. GST)
S$ 586.42
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
38 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 3P 1P + N, 3P + N 1P + N 3P, 3P 3P + N 1P + N, 1P + N
[In] Rated Current
5 A 1 A, 1 A 5 A 10 A, 1 A 5 A, 125 A, 63 A
Type of Measurement
Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average, Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Active and reactive energy Active and reactive power Current Voltage, Active energy Current Voltage Active power
Display Type
Backlit LCD, Remote LCD, TFT LCD, Without display, No Display
Standards
BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.16, IEC 62053-22:2020 EN 50470-1 IEC 60529 IEC 61557-12:2015 UL 61010-1 EN 50470-3 IEC 62053-24 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22:2020 IEC 62053-22:2020 EN 62052-22 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20, IEC 62052-31 IEC 62053-21 IEC 62053-23 IEC 62052-11, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…55 °C -20…55 °C, -25…55 °C - MID -25…70 °C - IEC, -25…70 °C - IEC
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top