Singapore
Contact Us
About Us
Login
|
Register
Search Keyword, Item or Model
Press
to jump to the search box
Shopping List
0
Cart
View All Categories
View All Brands
View All Spec Tables
SGD - S$
Home
/
All Categories
/
IO-Link Master
/
Lumberg Automation 935700002 0980 XSL 3912-121-007D-01F LioN-X 8xIO-Link Class a With Multiprotocol Including CC-Link
View Brand
Lumberg Automation 935700002 0980 XSL 3912-121-007D-01F LioN-X 8xIO-Link Class a With Multiprotocol Including CC-Link
Brand:
Lumberg Automation
Model:
935700002 0980 XSL 3912-121-007D-01F
Product Description
Lumberg Automation 935700002 0980 XSL 3912-121-007D-01F LioN-X 8xIO-Link Class a With Multiprotocol Including CC-Link
Product Family
: I/O Systems: Active - Standalone
Product Sub Family
: LioN-X
Item Description
: 0980 XSL 3912-121-007D-01F
Device Type
: IO-Link Master
Protocol
: Multiprotocol
I/O Function
: 8 IOL (Class A)
Bus Connection
: M12, 4-poles, D-coded
Power Connection (System Supply)
: M12 Power, 5-poles, L-coded
I/O Connection
: M12, 5-poles, A-coded
I/O Type
: IO-Link Master
General Data
Housing Material
: Metal, zinc die-cast
Housing Plating
: Nickel, matt
Housing Color
: Grey Metallic
Protection Degree / IP Rating
: IP65, IP67, IP69K
Potted
: Yes
Dimensions (W x H x D)
: 60 mm x 31 mm x 200 mm
Weight
: 480 g
Ambient Temperature (Operation)
: -40 °C to 70 °C
Ambient Temperature (Storage/Transport)
: -40 °C to 70 °C
Permissible Humidity (Operation)
: 5 % ... 95 % (For UL applications max. 80 %)
Permissible Humidity (Storage/Transport)
: 5 % ... 95 % (For UL applications max. 80 %)
Air Pressure (Operation)
: 80 kPa … 106 kPa (up to 2000 m above sea level)
Air Pressure (Storage/Transport)
: 80 kPa … 106 kPa (up to 2000 m above sea level)
Flammability Class
: UL 94 (IEC 61010)
Protection Class
: III, IEC 61140, EN 61140, VDE 0140-1
Pollution Degree
: 3 acc. to EN 60664-1, VDE 0110-1
Vibration Resistance
: 15 g / 5 -500 Hz
Shock Resistance
: 50 g / 11ms
Mean Time Between Failures (MTBF)
: 4616848
Contact Base Material
: M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
Contact Bearer Material
: PA / TPU
O-Ring Material
: FKM
Mounting
: 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
Fastening Torque (Fixing Screw)
: M4: 1 Nm
Fastening Torque (Ground Connection (FE))
: M4: 1 Nm
Fastening Torque (Bus Connection)
: M12: 0.5 Nm
Fastening Torque (Power Connection)
: M12: 0.5 Nm
Fastening Torque (I/O Connection)
: M12: 0.5 Nm
Included in Delivery
: Attachable Labels: 15x, Sealing Caps: 5x M12
Accessories to Order Separately
: Ethernet cable, mounting adapter, sensor/actuator cable, power cable
Supported Protocols
PROFINET
Connection
: M12 4-poles, D-coded
Number of Connections
: 2
Specification
: V2.3
Conformance Class
: C (CC-C)
Performance Class
: RT (switch supports IRT)
Netload Class
: III
Transmission Rate
: Fast Ethernet (10/100 Mbit/s), Full Duplex
Cycle Time / Update Rate
: min. 1 ms
Addressing
: DCP
Fast Startup (FSU)
: Supported, ≤ 4000 ms
EtherNet/IP
Protocol
: EtherNet/IP
Connection
: M12, 4-poles, D-coded
Number of Connections
: 2
Specification
: CIP V3.2x, EIP Adaption of CIP V1.2x
Transmission Rate
: Fast Ethernet (10/100 Mbit/s), Full Duplex
Cycle Time / Requested Packet Interval (RPI)
: min. 1 ms
Addressing
: BootP, DHCP, Rotary Address Switches
EtherCAT
Protocol
: EtherCAT
Connection
: M12 4-poles, D-coded
Number of Connections
: 2
Specification
: ETG.1000 V1.2
Transmission Rate
: Fast Ethernet (10/100 Mbit/s), Full Duplex
Cycle Time / Update Rate
: min. 250 µs
Mailbox Protocols
: CANopen over EtherCAT (CoE), File access over EtherCAT (FoE), Ethernet over EtherCAT (EoE)
CC-Link IE Field Basic
Protocol
: CC-Link IE Field Basic
Connection
: M12 LAN, 4-poles. D-coded
Number of Connections
: 2
Specification
: v2
Transmission Rate
: Fast Ethernet (100 Mbit/s), Full Duplex
Cycle Time / Update Rate
: min 1ms
Address Switches Range
: 0 to 99 dec
Number of stations
: 4
Supported Network Protocols
: SNMP, ACD, ARP, HTTP, IGMP, Ping, TCP/IP
Supported IIoT Protocols
: OPC UA, MQTT, CoAP, Syslog, Node Red
Modbus TCP
Protocol
: Modbus TCP
Connection
: M12, 4-poles, D-coded
Number of Connections
: 2
Specification
: Modbus application protocol V1.1b
OPC UA
: Cyclic data read/write, Diagnosis data, Event data
MQTT
: Cyclic data read/write, Diagnosis data, Event data
REST API
: Cyclic data read/write, Diagnosis data, Event data
CoAP
: Cyclic data read/write, Diagnosis data, Event data
IO-Link Master
Protocol
: IO-Link Master
Connection
: M12 5-poles, A-coded
Number of Connections
: 8
Specification
: v1.1.3 ready, IEC 61131-9
IO-Link Class
: Class A
Transmission Rate / COM Mode
: COM1, COM2, COM3
Parameter Storage
: Supported
Power Supply
Module Supply Voltage (Nominal)
: 24 V DC (SELV/PELV)
Module Supply Voltage (Range)
: 20V DC to 30 V DC
Reverse Polarity Protection
: Yes
Status Indicator (System Supply)
: LED green
Diagnostic Indicator
: LED red
Sensor Supply Voltage (Nominal)
: 24 V DC (SELV/PELV)
Sensor Supply Voltage (Range)
: 20V DC to 30 V DC
Status Indicator (Sensor Supply)
: LED green
Diagnostic Indicator
: LED red
Actuator Supply Voltage (Nominal)
: 24 V DC (SELV/PELV)
Actuator Supply Voltage (Range)
: 18 V DC to 30 V DC
Status Indicator (Actuator Supply)
: LED green
Diagnostic Indicator
: LED red
IO-Link Master Channels
Number of IO-Link Master Channels
: max. 8, configurable
Connection
: M12, 5-poles, A-coded
IO-Link Class A Ports
: 8x, X1 to X8
Cycle Time / Update Rate
: min. 1 ms for all channels at 32 Byte IN / OUT
Digital Input Channels
Number of Digital Input Channels
: up to 16
Connection
: M12, 5-poles, A-coded
Number of Ports
: 8x, X1 to X8
Nominal Voltage
: 24 V DC via US (module power supply)
Input Filter Time
: configurable
Digital Output Channels
Number of Digital Output Channels
: up to 16
Connection
: M12, 5-poles, A-coded
Number of Ports
: 8x, X1 to X8
Nominal Voltage
: 24 V DC via UL
Output Current per Channel
: max. 2 A
Electrical Isolation
US (System Supply Voltage) / FE
: 500 V DC
US / UL (Actuator Supply Voltage)
: 500 V DC
Bus connection / FE
: 2000 V DC
EMC Conformance
EMC Directive
: 2014/30/EU
EN 61000-4-2 Electrostatic Discharge (ESD)
: Criterion B; 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic Field
: Criterion A; Field intensity: 10 V/m
EN 61000-4-4 Fast Transients (Burst)
: Criterion B, 2 kV
Safety & Environmental Compliance
CE
: Yes
RoHS Compliant
: Yes
China RoHS-Compliant
: Yes
Approvals
UL
: cULus Listed, UL 61010-1
CSA
: Yes, via UL
PNO
: Yes
ODVA
: Yes
ETG
: Yes
IO-Link
: Yes
S$ 1,111.07
(exc. GST)
S$ 1,211.06
(inc. GST)
Units
Discount
Unit Price
1
-
S$ 1,111.07
Lead time of 126 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Add to Cart
Add To Shopping List
This item is sold by
SG-1400063614
View Shop
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
IO-Link Master from Lumberg Automation
Source & compare similar products
More from IO-Link Master
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Top