Shopping List
Shopping List
SGD - S$
Image
/
/
/
Lumberg Automation 934992002 0960 IOL 381-001 LioN-P, IO-Link I/O Hub, 16DI (8x M12), Class A, Metal, 60 Mm
Lumberg Automation 934992002 0960 IOL 381-001 LioN-P, IO-Link I/O Hub, 16DI (8x M12), Class A, Metal, 60 Mm
Image
Image
Product Description

Lumberg Automation 934992002 0960 IOL 381-001 LioN-P, IO-Link I/O Hub, 16DI (8x M12), Class A, Metal, 60 Mm

  • Product Family: I/O Systems: Active - Standalone
  • Product Sub Family: LioN-P
  • Item Description: 0960 IOL 381-001
  • Device Type: IO-Link Hub
  • Protocol: IO-Link
  • I/O Function: 16DI
  • Bus Connection: M12, 5-poles, A-coded
  • Power Connection (System Supply): M12, 5-poles, A-coded
  • Replacement for: 934992001
  • I/O Connection: M12, 5-poles, A-coded
  • I/O Type: Digital Input

General Data

  • Housing Material: Metal, Zinc Die-cast
  • Housing Plating: Nickel, matt
  • Housing Color: Grey Metallic
  • Protection Degree / IP Rating: IP65, IP67, IP69K
  • Potted: Yes
  • Dimensions (W x H x D): 60 mm x 31 mm x 159 mm
  • Weight: 390 g
  • Ambient Temperature (Operation): -20 °C to 70 °C
  • Ambient Temperature (Storage/Transport): -25 °C to 85 °C
  • Permissible Humidity (Operation): 5 % ... 95 % (For UL applications max. 80 %)
  • Permissible Humidity (Storage/Transport): 5 % ... 95 % (For UL applications max. 80 %)
  • Air Pressure (Operation): 80 kPa … 106 kPa (up to 2000 m above sea level)
  • Air Pressure (Storage/Transport): 80 kPa … 106 kPa (up to 2000 m above sea level)
  • Flammability Class: UL 94 (IEC 61010)
  • Protection Class: III, IEC 61140, EN 61140, VDE 0140-1
  • Pollution Degree: 3 acc. to EN 60664-1, VDE 0110-1
  • Vibration Resistance: 15 g / 5 -500 Hz
  • Shock Resistance: 50 g / 11ms
  • Mean Time To Failure (MTTF): 2111 years (acc. to Telcordia SR-332 (2011) 20°C)
  • Contact Base Material: M12, A-coded, CuSn, Gold-plated
  • Contact Bearer Material: PA
  • O-Ring Material: FKM

Mounting

  • 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.

Fastening Torque

  • Fixing Screw: M4: 1 Nm
  • Ground Connection (FE): M4: 1 Nm
  • Bus Connection: M12: 0.5 Nm
  • Power Connection: M12: 0.5 Nm
  • I/O Connection: M12: 0.5 Nm

Modbus TCP

  • Connection: M12, 5-poles, A-coded

IO-Link

  • Protocol: IO-Link
  • IO-Link Class: Class A
  • Number of Connections: 1
  • Specification: V1.1.2
  • Transmission Rate / COM Mode: COM 3 (230.4 kbps)
  • Cycle Time / Update Rate: min. 1 ms
  • Parameter Storage: Supported
  • Frame Type: Type_2_V
  • Process Data Length: 4 Bytes Input Data, 4 Bytes Output Data
  • Configuration: IODD, Process Data

Power Supply

  • Connection Module Supply Voltage: M12, 5-poles, A-coded
  • Number of Connections: 1
  • Current Carrying Capacity of Connector: max. 4 A
  • Module Supply Voltage (Nominal): 24 V DC (SELV/PELV)
  • Module Supply Voltage (Range): 18 V DC to 30 V DC
  • Current Consumption (typ.): 80 mA (at 24 V DC)
  • Reverse Polarity Protection: Yes
  • Status Indicator (System Supply): LED green
  • Diagnostic Indicator: LED red
  • Connection Sensor Supply Voltage: via Module Supply Connection
  • Current Carrying Capacity of Connector: max. 4 A
  • Sensor Supply Voltage (Nominal): 24 V DC (SELV/PELV)
  • Sensor Supply Voltage (Range): 18 V DC to 30 V DC
  • Reverse Polarity Protection: Yes
  • Status Indicator (Sensor Supply): LED green
  • Diagnostic Indicator: LED red

Digital Input Channels

  • Number of Digital Input Channels: max. 16, fixed
  • Connection: M12, 5-poles, A-coded
  • Number of Ports: 8x, X1 to X8
  • Channel Type: Type 1 acc. to IEC 61131-2
  • Sensor Current Supply: max. 700 mA per module (Consider 1L+ limitation of connected IO-Link Master)
  • Input Wiring: 2-, 3-wire
  • Nominal Voltage: 24 V DC via US (module power supply)
  • Nominal Current: typ. 5 mA
  • Sensor Type: PNP
  • Input Voltage Range "0" signal: -0.3V DC … 5 V DC
  • Input Voltage Range "1" signal: 15 V DC … 30 V DC
  • Input Filter Time: 0 to 3 ms, configurable
  • Protective Circuit: Electronically: Overload protection, short-circuit protection
  • Status Indicator (Inputs): LED white or yellow per channel

Electrical Isolation

  • US (System Supply Voltage) / FE: 500 V DC
  • Bus connection / FE: 500 V DC

EMC Conformance

  • EMC Directive: 2014/30/EU
  • EN 61000-4-2 Electrostatic Discharge (ESD): Criterion B; 4 kV contact discharge, 8 kV air discharge
  • EN 61000-4-3 Electromagnetic Field: Criterion A; Field intensity: 10 V/m
  • EN 61000-4-4 Fast Transients (Burst): Criterion B, 2 kV
  • EN 61000-4-5 Surge Voltage: Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
  • EN 61000-4-6 Conducted immunity: Criterion A; Test voltage 10 V
  • EN 55022 Radio Interference Properties: Class A

Safety & Environmental Compliance

  • CE: Yes
  • RoHS Compliant: Yes
  • China RoHS-Compliant: Yes

Approvals

  • UL: cULus Listed, UL 61010-1
  • UL-File: E230848
  • CSA: Yes, via UL
  • IO-Link: Yes

Notes

  • Protection Degree / IP Rating Note: Only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
  • System Power Supply Connection Note: Do not connect / disconnect under voltage!
S$ 395.04
(exc. GST)
S$ 430.60
(inc. GST)
UnitsDiscountUnit Price
1-S$ 395.04
Image
Lead time of 126 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
This item is sold by
Image
SG-1400063614
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
IO-Link Hubs from Lumberg Automation
Source & compare similar products
More from IO-Link Hubs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top