Technical Data Sheets
Product Description

This Acti9 SD electric auxiliary is a remote fault indicator contact. It is dedicated to Acti9C120, C60H-DC. It indicates the position of the associated device in the event of electrical fault or action on the tripping auxiliary. The width in 9mm. The Ue rated operational voltage is 24VAC to 415VAC or 24VDC to 130VDC. The operating frequency is 50Hz or 60Hz. The Ie rated operational current is 6A under 24VDC, 2A under 48VDC, 1.5A under 60VDC, 1A under 130VDC. The Ie rated operational current is 6A under 24VAC to 240VAC, 3A under 415VAC. There is a mechanical state indicator and a test function button on the front face. Be careful, this device is not compatible with an ID residual current circuit breaker. The operating temperature is -25°C to + 50°C. The storage temperature is -40°C to + 85°C. This product complies with IEC/EN 60947-5-1 standard and EN 62019-2 standard only for C120.

S$ 32.44
(exc. GST)
S$ 35.36
(inc. GST)
Image
Lead time of 1 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
This item is sold by
Image
SG-4021235887
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, Acti 9, C6-, Tesys, Multi 9
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP2X, IP20 conforming to IEC 60529, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529, IP20 conforming to EN/IEC 60947-5-1
Ambient Air Temperature for Operation
-5…60 °C, -25…50 °C, -20…50 °C, -35…70 °C, -25…60 °C
Ambient Air Temperature for Storage
-50…80 °C, -50…70 °C, -40…85 °C, -60…80 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top