Quality Product ~ Made in Taiwan
TM-801 CO meter is used for measuring the CO levels up to 1000ppm.
Carbon monoxide (CO) is a poisonous gas that has no smell, colour or taste. But it is very dangerous and reduces the oxygen-carrying capacity of blood that causes you unwell, illness and death.
Features:
- 4 digital LCD with maximum 1000 counts.
- CO range: 0 ~ 1,000ppm.
- Temperature range: -20~50 ºC (-4~122 ºF).
- Sample rate: 1 time/second
- Dual and digital display of the CO and temperature measuring
- Max/Min/Average Hold.
- Data Hold.
- Low battery indication
- Auto power off with disable function.
- Adjustable alarm: Adjustable alarm threshold level (25 /35 /50 /100 /250 /400 /800 /Randomly adjustable); Enable/Disable alarm
- LED Backlight.
- Auto power OFF and disable function.
Specifications:
- CO Measurement:
- Range: 0 ~ 1000ppm
- Resolution: ±1ppm
- Accuracy: ±5% or ±2ppm
- Repeatability: < 2%
- Response time※: < 30 seconds.
- Zero drift in long term: < 5ppm
- Sensitivity drift: < 5% (per year)
- Typical sensor life: 3 years
- Temperature Measurement:
- Range: -20~50℃/-4~122℉
- Resolution: ±0.1℃/±0.1℉
- Accuracy: ±1.0℃/±1.8℉
- Power supply: 1.5V UM-4(AAA) battery × 6 PCS or AC100~240V or DC Adaptor 9V/0.5A(9mm).
- Battery life: approx 90 hours.
- Operating Temperature & Humidity: -20°C to +50°C, <80% RH.
- Storage Temperature & Humidity : -10°C to +50°C, <70% RH.
- Dimension: 156×73×35mm(LxWxH).
- Weight: approx 250g (Batteries not included).
Standard accessories:
- UM-4(AAA)1.5V battery ×6 PCS, user’s manual, carrying pouch.
CO LEVELS AND STANDARD:
Carbon monoxide content in the air | Inspiration time | Symptoms and applicable standard
- 0-1 ppm : Normal background levels.
- 9 ppm : Maximum indoor air quality level.
- 35 ppm | 8 hours : The average exposure level per U.S. OSHA workplace standards.
- 50 ppm | 8 hours : The maximum average exposure of the U.S. OSHA workplace standards.
- 0.01%(100 ppm) | 2~3 hours : Evacuate people from enclosed space if the CO concentration exceeds 100 ppm per OSHA exposure limit. Mild headache.
- 0.04%(400 ppm) | 1~2 hours : Headache occur in 2.5 hours to 3.5 hours.
- 0.08%(800 ppm) | 45-min : Dizziness, nausea, cramps(convulsions).
- 0.16%(1600 ppm) | 20-min : Headache, dizziness and will be dead within 2 hours.
- 0.32%(3200 ppm) | 5~10 min : Headache, dizziness, vomiting and will be dead in 30 minutes.
- 0.64%(6400 ppm) | 1~2 min : Headache, dizziness and will be dead within10 to 15 minutes.
- 1.28%(12800 ppm) | 1~3 min : Cause death.
Standards Certification: