This Harmony XPE consists of a single step blue metal safety footswitch. It has 1 x NC + 1 x NO contacts. It preserves the ergonomy of your machines, while ensuring their compliance with the latest safety standards. It provides long life in harsh conditions thanks to its resistance to hydraulic oil and various greases.
Main:
- Range of product: Harmony XPE
- Product or component type: Foot switch
- Material: Metal
- Foot switch type: Single foot switch
- Device short name: XPEM
- Trigger mechanism: Without trigger mechanism
- Contact operation: 1 step
- Contacts type and composition: 1 NC + 1 NO
- Colour: Blue
Complementary:
- Positive opening: With conforming to EN/IEC 60947-5-1 appendix K
- Connections - Terminals:
- Screw clamp terminal, <= 1 x 2.5 mm² with or without cable end
- Screw clamp terminal, <= 2 x 1.5 mm² with or without cable end
- Cable entry: 2 entries tapped for Pg 16 cable gland
- Mechanical Durability: 15,000,000 cycles
- Rated operational current ([Ie]):
- 3 A, 240 V, AC-15, A300
- 0.27 A, 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
- Rated insulation voltage ([Ui]):
- 500 V (pollution degree 3) conforming to EN/IEC 60947-1
- 500 V (pollution degree 3) conforming to NF C 20-040 group C
- 500 V (pollution degree 3) conforming to VDE 0110 group C
- 300 V conforming to UL 508
- 300 V conforming to CSA C22.2 No 14
- Rated impulse withstand voltage ([Uimp]): 6 kV conforming to EN/IEC 60947-1
- Maximum resistance across terminals:
- 25 MOhm conforming to IEC 60255-7 category 3
- 25 MOhm conforming to NF C 93-050 method A
- Short-circuit protection:
- 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
- 10 A cartridge fuse type gG conforming to VDE 0660-200
- Rated operational power in W:
- 10 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 24 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 4 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 120 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- 7 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 48 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
- Net weight: 1.2 kg
Environment:
- Standards:
- VDE 0660-200
- EN/IEC 60947-5-1
- Product certifications: FIMKO, CSA
- Protective treatment: TC
- Ambient air temperature:
- Operation: -25…70 °C
- Storage: -40…70 °C
- Vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
- Shock resistance:
- 150 gn conforming to NF E 09-031
- 20 gn conforming to IEC 60068-2-27
- Overvoltage category:
- Class I conforming to EN/IEC 61140
- Class I conforming to NF C 20-030
- IP degree of protection: IP66 conforming to IEC 60529