Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric LP1K0910BD Contactor, Tesys K, 3P, AC-3/AC-3e, 440V, 9A, 1NO Aux, 24V Dc Coil,screw Clamps
Schneider Electric LP1K0910BD Contactor, Tesys K, 3P, AC-3/AC-3e, 440V, 9A, 1NO Aux, 24V Dc Coil,screw Clamps
Image
Image
Specifications
infotip-icon
View other Contactors dimensions or variations
Please select at least one specification below.
Device Short Name
LP1K
Depth
57 mm
Poles Description
3P
Contactor Application
Motor control Resistive load
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
8 kV
This spec is not available in the specification table.
Mounting Support
Rail Plate
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
This spec is not available in the specification table.
Height
58 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP2X
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-25…50 °C
This spec is not available in the specification table.
Mechanical Durability
10 Mcycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-50…80 °C
This spec is not available in the specification table.
Electrical Durability
1.3 Mcycles 9 A AC-3 at Ue <= 440 V 1.3 Mcycles 9 A AC-3e at Ue <= 440 V 0.16 Mcycles 20 A AC-1 at Ue <= 690 V 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
This spec is not available in the specification table.
Operating Altitude
2000 m without derating
This spec is not available in the specification table.
Tightening Torque
0.8…1.3 N.m - on screw clamp terminals Philips No 2 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC <= 400 Hz Signalling circuit: <= 690 V AC <= 400 Hz
This spec is not available in the specification table.
[Ie] Rated Operational Current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
24 V DC
This spec is not available in the specification table.
Heat dissipation
1.3 W
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Utilisation Category
AC-3 AC-3e AC-1 AC-4
This spec is not available in the specification table.
Motor Power Kw
2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440/690 V AC 50/60 Hz AC-3 2.2 kW at 220...230 V AC 50/60 Hz AC-3e 4 kW at 380...415 V AC 50/60 Hz AC-3e 4 kW at 440/690 V AC 50/60 Hz AC-3e 2.2 kW at 220...230 V AC 50/60 Hz AC-4 4 kW at 380...415 V AC 50/60 Hz AC-4 4 kW at 440/690 V AC 50/60 Hz AC-4
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
20 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit
This spec is not available in the specification table.
Irms Rated Making Capacity
110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
This spec is not available in the specification table.
Rated Breaking Capacity
110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
This spec is not available in the specification table.
Associated Fuse Rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
This spec is not available in the specification table.
Average Impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Type
DC standard
This spec is not available in the specification table.
Control Circuit Voltage Limits
Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: >= 0.10 Uc (at <50 °C)
This spec is not available in the specification table.
Operating Time
30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
This spec is not available in the specification table.
Auxiliary Contact Composition
3600 cyc/h
This spec is not available in the specification table.
Maximum Operating Rate
1 NO
This spec is not available in the specification table.
Auxiliary Contacts Type
type instantaneous 1 NO
This spec is not available in the specification table.
Minimum Switching Voltage
17 V for signalling circuit
This spec is not available in the specification table.
Minimum Switching Current
5 mA for signalling circuit
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm for signalling circuit
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
This spec is not available in the specification table.
Inrush Power In W
3 W (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In W
3 W at 20 °C
This spec is not available in the specification table.
Power Pole Contact Composition
3 NO
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors from SCHNEIDER ELECTRIC
Source & compare similar products
More from Contactors
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top