Specification:
Operating indicator : Mechanical indicator
Degree of protection : Closed type (cover)
Terminal structure : Plug-in terminal
Coil Coil ratings : 220 VAC 50 Hz 12.1 mA
220 VAC 60 Hz 10.5 mA
Coil resistance : 3550 Ω
Operate voltage (Set voltage) : 80% max.
Release voltage (Reset voltage) : 25% min. (50 Hz)
30% min. (60 Hz)
Maximum voltage : 110%
Power consumption Approx. : 2.7 VA 50 Hz/Approx. 2.3 VA 60 Hz
Contact Contact rated load : 250 VAC 10 A (NO contact: Resistive load)
250 VAC 5 A (NC contact: Resistive load)
250 VAC 7 A (Inductive load (cosφ = 0.4))
30 VDC 10 A (NO contact: Resistive load)
30 VDC 5 A (NC contact: Resistive load)
Max. contact voltage : 250 VAC
250 VDC
Max. contact current AC: 10 A
DC: 10 A
Maximum switching power 2500 VA (NO contact: Resistive load)
1250 VA (NC contact: Resistive load)
300 W (NO contact: Resistive load)
150 W (NC contact: Resistive load)
Contact form DPDT
Contact method Single
Contact material AgSnIn
Performance
Contact resistance 100 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Reset time 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/h
Rated load: 1800 time/h
Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 2500 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2500 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)