Schneider Electric XPSCM1144 single-beam photo-electric Sensors - Module XPS-CM

This XPSCM safety module is for monitoring of single-beam photo-electric sensors and has a built-in "muting" function. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2.

Main

  • Range of Product: Telemecanique Safety Light Curtains XUSL
  • Product or Component Type: Safety Module
  • Safety Module Name: XPSCM
  • Safety Module Application: For monitoring of single beam photo-electric sensor
  • Function of Module: Built-in muting
  • Safety Level:
    • Can reach Category 2 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
    • Can reach SILCL 1 with the appropriate control system and correctly wired conforming to EN/IEC 62061
    • Can reach PL = c with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
  • Safety Reliability Data:
    • MTTFd (Mean Time To Dangerous Failure) = 16.6 years conforming to EN/ISO 13849-1
    • DC (Diagnostic Coverage) = 95.5% conforming to EN/ISO 13849-1
    • PFH (Probability of Dangerous Failure per Hour) = 3.12E-7 1/h conforming to EN/IEC 61508
    • PFHd (Probability of Dangerous Failure per Hour) = 3.12E-7 1/h conforming to EN/IEC 62061
  • Number of Inputs:
    • 2 (terminals MA, MB) for muting function
    • 4 (terminals Z1, Z2, Z3, Z4) for sensor
  • Input Voltage:
    • 24 V DC for sensor
    • 24 V DC (terminals U+, U-) for muting function
  • Input Compatibility:
    • XC limit switch for muting function
    • XU2M18PP340... for muting function
    • XU2S18PP340... (infrared) for sensor
    • XU9M18PP340... for muting function
  • Connections - Terminals: Various captive screw clamp terminals for different cable types and configurations
  • Output Type: Relay 2 NO (Normally Open) (13-14, 23-24), volt-free
  • Number of Additional Circuits: 0
  • Rated Supply Voltage ([Us]): 24 V DC with a tolerance of -20% to +20%

Complimentary

  • Sensor Power Supply:
    • U+, U-: 24 V DC
  • Maximum Supply Current for Sensors:
    • 200 mA
  • Input Current:
    • 200 mA for muting function
  • Synchronization Time Between Inputs:
    • 3 s (+/- 20 %) for the activation of the MA/MB muting signal
  • Muting Maximum Duration:
    • 60 s (-10...30 %)
  • Maximum Line Resistance:
    • 10 Ohm for sensor power supply
  • Breaking Capacity:
    • 180 VA holding AC-15 C300 relay output
    • 1800 VA inrush AC-15 C300 relay output
    • 20 mA at 24 V for solid-state output
    • 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
  • Associated Fuse Rating:
    • 4 A gG for relay output conforming to DIN VDE 0660 part 200
    • 4 A gG for relay output conforming to EN/IEC 60947-5-1
    • 6 A fast blow for relay output conforming to DIN VDE 0660 part 200
    • 6 A fast blow for relay output conforming to EN/IEC 60947-5-1
  • Minimum Output Current:
    • 10 mA for relay output
  • Minimum Output Voltage:
    • 17 V for relay output
  • Maximum Response Time on Input Open:
    • 25 ms
  • Local Signaling:
    • 1 LED for electronic internal fuse status
    • 1 LED for restarting function
    • 1 LED for safety outputs closed function
    • 1 LED for safety outputs open function
    • 1 incandescent lamp for muting power consumption: 4…6.5 W
  • Output Thermal Current:
    • 5.6 A per relay
    • 11 A maximum
  • Maximum Power Consumption in W:
    • 15 W
  • Protection Type:
    • Electronic internal fuse
  • [Ui] Rated Insulation Voltage:
    • 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2
    • 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1
  • [Uimp] Rated Impulse Withstand Voltage:
    • 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2
    • 4 kV overvoltage category III conforming to EN/IEC 60947-5-1

Environment

  • Ambient Air Temperature:
    • For Operation: -10…55 °C
    • For Storage: -25…85 °C
  • IP Degree of Protection:
    • IP20 (terminals) conforming to IEC 60529
    • IP40 (enclosure) conforming to IEC 60529


RM 72,184.48
Quantity:
EA
Img
MOQ of 20 EA
Img
Bundle of 1 EA
This item is sold by
Image
Schneider Electric
0
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Safety Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Safety Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top