70 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Width
105 mm
This spec is not available in the specification table.
Device Short Name
GV5P
This spec is not available in the specification table.
Product Name
TeSys GV5
TeSys Giga
This spec is not available in the specification table.
Depth
155 mm
This spec is not available in the specification table.
Range of Product
TeSys GV5
This spec is not available in the specification table.
Device Application
Motor protection
This spec is not available in the specification table.
Connection Pitch
35 mm without spreaders
This spec is not available in the specification table.
Utilisation Category
Category A conforming to IEC 60947-2
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to EN/IEC 60947-2
This spec is not available in the specification table.
Standards
EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
This spec is not available in the specification table.
Connections - Terminals
Bars
Lugs
This spec is not available in the specification table.
Height
161 mm
This spec is not available in the specification table.
Mechanical Durability
40000 cycles
This spec is not available in the specification table.
Electrical Durability
20000 cycles for AC-3 at 400/415 V In
This spec is not available in the specification table.
Tightening Torque
15 N.m M8 screw type
This spec is not available in the specification table.
Motor Power kW
55…75 kW at 400/415 V AC 50/60 Hz
75…90 kW at 500 V AC 50/60 Hz
90…110 kW at 660/690 V AC 50/60 Hz
This spec is not available in the specification table.
[Ith] conventional free air thermal current
150 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
9.2 W
This spec is not available in the specification table.
Maximum operating rate
25 cyc/h
This spec is not available in the specification table.
Product certifications
IECEE CB Scheme
EAC (pending)
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
This spec is not available in the specification table.
[Ics] rated service short-circuit breaking capacity
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Magnetic tripping current
2250 A
This spec is not available in the specification table.
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
This spec is not available in the specification table.
Rated duty
Continuous
This spec is not available in the specification table.
IK Degree of Protection
IK07 conforming to IEC 62262