Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric Residual Current Circuit Breaker (rccb), Acti9 Iid, 4P, 63A, Ac Type, 100mA A9R12463
Schneider Electric Residual Current Circuit Breaker (rccb), Acti9 Iid, 4P, 63A, Ac Type, 100mA A9R12463
Image
Image
Product Description

SCHNEIDER ELECTRIC Residual Current Circuit Breaker (rccb), Acti9 Iid, 4P, 63A, Ac Type, 100mA A9R12463

  • This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with In rated current of 63A, AC type protection class and a 100mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 15000 cycles. The mechanical endurance is up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
  • Range:Acti9
  • Product name:Acti9 iID
  • Product or component type:Residual current circuit breaker (RCCB)
  • Device short name:IID
  • Poles description:4P
  • Neutral position:Left
  • [In] rated current:63 A
  • Network type:AC
  • Earth-leakage sensitivity:100 mA
  • Earth-leakage protection time delay:Instantaneous
  • Earth-leakage protection class:Type AC
AU $ 74.29
UnitsDiscountUnit Price
1 ~ 9-AU $ 74.29
10++9% OFFAU $ 67.54
Image
Lead time of 2 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Residual current devices - RCDs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Residual current devices - RCDs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top