Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric GV4AE11 Auxiliary Contact, Tesys GV4, 690VAC, 1 NO/NC
Schneider Electric GV4AE11 Auxiliary Contact, Tesys GV4, 690VAC, 1 NO/NC
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Rated Current
5 A <= 690 V AC-12 conforming to IEC 60947-5-1 5 A <= 48 V AC-15 conforming to IEC 60947-5-1 4 A 110/127 V AC-15 conforming to IEC 60947-5-1 3 A 220/240 V AC-15 conforming to IEC 60947-5-1 2.5 A 380...440 V AC-15 conforming to IEC 60947-5-1 0.11 A 660/690 V AC-15 conforming to IEC 60947-5-1 5 A <= 24 V DC-12 conforming to IEC 60947-5-1 2.5 A 48 V DC-12 conforming to IEC 60947-5-1 0.6 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.3 A 250 V DC-12 conforming to IEC 60947-5-1 2.5 A <= 24 V DC-12 conforming to IEC 60947-5-1 1.2 A 48 V DC-12 conforming to IEC 60947-5-1 0.35 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.05 A 250 V DC-12 conforming to IEC 60947-5-1 1 A <= 24 V DC-12 conforming to IEC 60947-5-1 0.2 A 48 V DC-12 conforming to IEC 60947-5-1 0.05 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.03 A 250 V DC-12 conforming to IEC 60947-5-1
Range
TeSys
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1
[Ue] Rated Operational Voltage
<= 690 V
Mounting Type
Internal mounting
This spec is not available in the specification table.
Device Short Name
GV4AE
This spec is not available in the specification table.
Device Application
Signalling
This spec is not available in the specification table.
Connections - Terminals
Spring terminals 1 0.5…1.5 mm² - cable stiffness: flexible without cable end
This spec is not available in the specification table.
Mechanical Durability
40000 cycles
This spec is not available in the specification table.
[Ith] conventional free air thermal current
5 A conforming to IEC 60947-5-1 5 A conforming to CSA C22.2 No 14 5 A conforming to UL 508
This spec is not available in the specification table.
Associated fuse rating
5 A gG at 690 V conforming to IEC 60947-5-1
This spec is not available in the specification table.
Auxiliary contact composition
1 NO/NC
This spec is not available in the specification table.
Minimum switching voltage
17 V
This spec is not available in the specification table.
Minimum Switching Current
2 mA
This spec is not available in the specification table.
Range compatibility
TeSys TeSys GV4 TeSys TeSys BV4
This spec is not available in the specification table.
Wire Stripping Length
8 mm
This spec is not available in the specification table.
Rated power in W
DC-12: 120 W 24 V conforming to IEC 60947-5-1 DC-12: 120 W 48 V conforming to IEC 60947-5-1 DC-12: 66 W 110 V conforming to IEC 60947-5-1 DC-12: 75 W 250 V conforming to IEC 60947-5-1
This spec is not available in the specification table.
Rated power in VA
120 VA AC-12 at 24 V conforming to IEC 60947-5-1 240 VA AC-12 at 48 V conforming to IEC 60947-5-1 635 VA AC-12 at 110/127 V conforming to IEC 60947-5-1 1200 VA AC-12 at 230/240 V conforming to IEC 60947-5-1 2200 VA AC-12 at 380/440 V conforming to IEC 60947-5-1 3450 VA AC-12 at 660/690 V conforming to IEC 60947-5-1
This spec is not available in the specification table.
Product Description
AU $ 34.07
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, Acti 9, C6-, Tesys, Multi 9
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP2X, IP20 conforming to IEC 60529, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529, IP20 conforming to EN/IEC 60947-5-1
Ambient Air Temperature for Operation
-5…60 °C, -25…50 °C, -20…50 °C, -35…70 °C, -25…60 °C
Ambient Air Temperature for Storage
-50…80 °C, -50…70 °C, -40…85 °C, -60…80 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top