Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric GV3P80 Motor Circuit Breaker,tesys Deca Frame 3,3P,70-80A,thermal Magnetic,everlink Terminals
Schneider Electric GV3P80 Motor Circuit Breaker,tesys Deca Frame 3,3P,70-80A,thermal Magnetic,everlink Terminals
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Motor Protection Circuit Breakers dimensions or variations
Please select at least one specification below.
Poles
3P
Rated Current
80 A
Colour
Dark grey
Trip Unit Technology
Thermal-magnetic
Control Type
Rotary handle
Range
TeSys Deca
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-2
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-20…60 °C
Ambient Air Temperature for Storage
-40…80 °C
Operating Altitude
3000 m
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz
Breaking Capacity
65 kA Icu at 230/240 V AC 50/60 Hz 50 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz
This spec is not available in the specification table.
Width
55 mm
This spec is not available in the specification table.
Device Short Name
GV3P
This spec is not available in the specification table.
Product Name
TeSys GV3 TeSys Deca
This spec is not available in the specification table.
Depth
136 mm
This spec is not available in the specification table.
Device Application
Motor protection
This spec is not available in the specification table.
Network Type
AC
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Utilisation Category
AC-3 conforming to IEC 60947-4-1
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-1
This spec is not available in the specification table.
Standards
EN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1
This spec is not available in the specification table.
Height
132 mm
This spec is not available in the specification table.
Mechanical Durability
50000 cycles
This spec is not available in the specification table.
Electrical Durability
20000 cycles for AC-3 at 415 V In
This spec is not available in the specification table.
Tightening Torque
5 N.m - on screw clamp terminal
This spec is not available in the specification table.
Fixing Mode
35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws)
This spec is not available in the specification table.
Motor Power kW
45 kW at 400/415 V AC 50/60 Hz maximum peak current 750 A 45 kW at 500 V AC 50/60 Hz maximum peak current 750 A 55 kW at 690 V AC 50/60 Hz maximum peak current 750 A
This spec is not available in the specification table.
[Ith] conventional free air thermal current
80 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
8 W
This spec is not available in the specification table.
Product certifications
CCC CSA EAC ATEX LROS (Lloyds register of shipping) BV ABS DNV-GL UKCA
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Shocks: 5 Gn for 11 ms contactor open Shocks: 30 Gn for 11 ms contactor closed Vibrations: 4 Gn, 5...300 Hz
This spec is not available in the specification table.
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz 60 % at 400/415 V AC 50/60 Hz 60 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz
This spec is not available in the specification table.
Thermal protection adjustment range
70…80 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Magnetic tripping current
1120 A
This spec is not available in the specification table.
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
This spec is not available in the specification table.
Rated duty
Continuous conforming to IEC 60947-4-1
This spec is not available in the specification table.
IK Degree of Protection
IK09 enclosure
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Protection Circuit Breakers from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Protection Circuit Breakers
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top