Schneider Electric A9N61501 Miniature Circuit Breaker (mcb), Acti9 C60H-DC, 1P, 1A, C Curve, 6kA (IEC/EN 60947-2)
Schneider Electric A9N61501 Miniature Circuit Breaker (mcb), Acti9 C60H-DC, 1P, 1A, C Curve, 6kA (IEC/EN 60947-2)
Image
Image
Technical Data Sheets
Specifications
infotip-icon
View other Miniature Circuit Breakers - MCBs dimensions or variations
Please select at least one specification below.
Standards
EN/IEC 60898-1, EN/IEC 60947-2, IEC 60529
Breaking Capacity
10kA at 220VDC
Rated Current
1A
This spec is not available in the specification table.
Rated Voltage
250VDC
This spec is not available in the specification table.
Poles
1
This spec is not available in the specification table.
Trip Curve
C
This spec is not available in the specification table.
Weight
0.128kg
This spec is not available in the specification table.
Operating Temperature Range
-25°C to 70°C
This spec is not available in the specification table.
Dimensions
2 pitches of 9mm
This spec is not available in the specification table.
Mounting Type
DIN Rail
This spec is not available in the specification table.
Product Description

SCHNEIDER ELECTRIC Miniature Circuit Breaker (mcb), Acti9 C60H-DC, 1P, 1A, C Curve, 6kA (IEC/EN 60947-2) A9N61501

  • This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 1P, rated current 1A and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN 60947-2 standard and 10kA at 220VDC conforming to EN 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. This miniature circuit breaker protects circuit against short circuit and overload current. This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The weight is 0.128kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
  • Range:Acti9
  • Product name:Acti9 C60H-DC
  • Product or component type:Miniature circuit-breaker
  • Device short name:C60H-DC
  • Device application:Distribution
  • Poles description:1P
  • Number of protected poles:1
  • [In] rated current:1 A at 25 °C
  • Network type:DC
  • Trip unit technology:Thermal-magnetic
  • Curve code:C
AU $ 607.25
Image
Restocking
Contact us at enquiry@eezee.com.sg or +65 6797 9688 for more details. Item will take longer than normal to be delivered.
Quantity:
EA
Img
MOQ of 12 EA
Img
Bundle of 12 EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
MASTERPACT NW, Easy 9, PowerPact, Multi 9, Resi 9
Poles Description
2P, 1P+N, 3P, 3P+N, 1P
[In] Rated Current
2 A, 1.6 A, 3.5 A, 3.2 kA, 24 A
Breaking Capacity
10 kA, 20 kA, 25 kA, 30 kA, 20 kA, 3 kA, 15 kA, 30 kA
Standards
EN 60898-1 EN 60947-2 IEC 60947-2 IEC 60898-1, EN 60947-2 EN 60898-1 IEC 60947-2 IEC 60898-1, EN/IEC 60898-1, EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN 60947-2 IEC 60898-1 EN 60898-1 IEC 60947-2
Magnetic Tripping Limit
3...5 x In, 5...10 x In, 4 x In +/- 20 %, 10...14 x In, 12 x In +/- 20 %
Connection - Terminals
Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule, Tunnel type terminals (downstream) 0.5…35 mm² rigid, Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Miniature Circuit Breakers - MCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Miniature Circuit Breakers - MCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top