Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Fuji K244X-2V Block Contact for Switch Limit
Fuji K244X-2V Block Contact for Switch Limit
Image
Image
Product Description

Fuji K244X-2V Block Contact for Switch Limit

FUJI K244 type limit switches have an excellent performance. K244 limit switches employ a highly dependable and long lasting double break silver alloy contact system. These can be expected to perform more than 10 million mechanical operations and a rate of 3,000 operations per hour. The large variety of operating types such as standard stroke, snap-action type, make-before-break type and extended stroke type, etc. allow you to select a suitable limit switch that fully meets your requirements. K244 limit switches are widely used for industrial machinery such as machine tools, printing machines, conveyors, automatic machines and door interlocking and similar applications. The aluminum die-cast housing can also be supplied in an oil and water proof version.


  1. Insulation resistance: Over 100MS2 at 500V DC
  2. Dielectric strength: 2500V AC rms 1 minute
  3. Max. operating cycle: 3000 cycles per hour
  4. Life expentancy Mechanical: 10 million operations
  5. Electrical:
  • K244-2, 2U and 2V 3.3 million operations at 24 t 550V AC 3A
  • K244-2S 1.3 million operations at 24 to 550V AC 3A
AU $ 27.16
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Contact Block
41 Items
contact-block-img
Contacts type and composition
1 NC + 1 NO, 2 NC, 1 C/O + 1 NO, 2 NO + 1 C/O, 1 NC + 2 NO
Range Of Product
Harmony 9001K Harmony 9001SK, Harmony XB6, Harmony XAC, Harmony XAL Harmony XAPS, Harmony XAPS Harmony XAL
Standards
IEC 60947-3 CSA C22.2 No 14 EN 60947-3, EN/IEC 60947-5-1 UL 508 EN/IEC 60204-32 CSA C22.2 No 14, CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508, IEC 60947-5-1 CSA C22.2 No 14 IEC 60947-1 UL 508 IEC 60947-5-5 JIS C8201-5-1 IEC 60947-5-4 JIS C8201-1, IEC 60947-5-5 IEC 60947-5-4 UL 508 JIS C8201-5-1 IEC 60947-1 CSA C22.2 No 14 IEC 60947-5-1 JIS C8201-1
[Ui] Rated Insulation Voltage
600 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to EN/IEC 60947-1, 500 V (pollution degree 3) conforming to IEC 60947-1, 600 V conforming to CSA
[Uimp] Rated Impulse Withstand Voltage
4 kV conforming to IEC 60947-1, 6 kV conforming to EN 60947-1, 6 kV conforming to IEC 60947-1, 2.5 kV conforming to IEC 60947-1, 4 kV conforming to EN/IEC 60947-1
[Ie] Rated Operational Current
3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1, 2 A at 230 V, AC-15, A600 conforming to IEC 60947-5-1 0.2 A at 110 V, DC-13, Q600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600-Q600 conforming to NEMA 0.55 A at 125 V, DC-13, A600-Q600 conforming to NEMA, 3 A at 120 V, AC-15, B300 1.5 A at 240 V, AC-15, B300 0.1 A at 250 V, DC-13, R300 0.22 A at 125 V, DC-13, R300
Contact Operation
Positive opening, Standard, Staggered Snap action, Snap action Staggered, Slow-break Staggered
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contact Block from Fuji Electric
Source & compare similar products
More from Contact Block
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top