Conductor:
- AWG: 23
- Stranding: Solid
- Material: BC - Bare Copper
- No. of Pairs: 4
- Conductor Count: 8
- Total Number of Pairs: 4
Insulation:
- Type: Dielectric
- Material: PO - Polyolefin
- Nominal Diameter: 1.35 mm
- Bonded-Pair: Yes
Construction and Dimensions:
- Min Elongation at Break of Conductors: 10%
- Min Elongation at Break of Insulation: 100%
- Min Elongation at Break of Jacket: 100%
- Min Tensile Strength of Jacket: 9 MPa
Electrical Characteristics:
- Conductor DCR:
- Max. Conductor DCR: 95 Ohm/km
- Max DCR Unbalanced Between Pairs [%]: 4%
- Max. DCR Unbalanced Within Pair [%]: 2%
- Capacitance:
- Max. Capacitance Unbalance: 1,600 pF/m
- Max. Mutual Capacitance: 56 pF/m
- Impedance:
- Nominal Characteristic Impedance: 100 Ohm
- Delay:
- Max. Delay Skew: 40 ns/100m
- Min. Velocity of Propagation: 60%
- Transfer Impedance:
- Frequency [MHz]:
- 1 MHz: Max. 50 mOhm/m (Grade 2)
- 10 MHz: Max. 100 mOhm/m
- 30 MHz: Max. 200 mOhm/m
- 100 MHz: Max. 1000 mOhm/m
- Current:
- Max. Recommended Current: 1.5 Amps per Conductor
- Voltage:
Temperature Range:
- Installation Temp Range: 0°C to +50°C
- Operating Temp Range: -30°C to +60°C
- Mechanical Characteristics:
- Bulk Cable Weight: 51 kg/km
- Max. Pull Tension: 110 N
- Min Bend Radius During Installation: 60 mm
- Min Bend Radius During Operation: 30 mm
Standards:
- IEC Compliance: ISO/IEC 11801-1
- CPR Euroclass: Fca
- CENELEC Compliance: EN 50173-1
- Data Category: Category 6
- ANSI Compliance: ANSI/TIA 568.2-D (2018)
- IEEE Compliance: PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Applicable Environmental and Other Programs:
- Environmental Space: Indoor/Outdoor
- EU RoHS Compliance Date: 2011-12-07
- Flammability, LS0H, Toxicity Testing:
- Burning Load: 1000 kJ/m
- IEC 60754-1 (EN50267-1) - Halogen Amount: Zero
- IEC 60754-2 (EN50267-2) - Halogen Acid Gas Amount:
- Max. Conductivity: 2.5 µS/mm
- Min. pH: 4.3